New Year Special Sale - Limited Time 70% Discount Offer - Ends in 0d 00h 00m 00s - Coupon code: mxmas70

Home > HP > HPE Technical Certification > HPE0-S60

HPE0-S60 Delta - HPE Compute Solutions Question and Answers

Question # 4

Which tool can be used to evaluate me health of an HPE Oneview appliance before proceeding with an appliance updated.

A.

HPE Composer Maintenance Console

B.

HPE OneView Update Readiness Checker

C.

HPE OneView Global Dashboard

D.

HPE OneView Firmware Compliance Report

Full Access
Question # 5

Your customer has experience with utilization sampling for HPE Virtual Connect SE 100 Gb F32 Module for HPE Synergy. They have recently purchased HPE VC FC modules.

What must you be aware of regarding utilization sampling for the new modules?

A.

Utilization sampling for HPE VC FC modules must be enabled manually using CLI.

B.

For HPE VC FC modules, utilization sampling is always enabled and cannot be disabled

C.

For HPE VC FC modules, utilization sampling can be enabled once appropriate license is applied

D.

Utilization sampling works the same way tor any type of HPE Synergy interconnect modules

Full Access
Question # 6

Your customer used to manage their HPE 3PAR arrays using HPE OneView Now they have replaced these arrays HPE Primera.

How does managing the new arrays compare to managing their old arrays?

A.

HPE OneView offers additional functionalities for HPE Primera like CPG management

B.

HPE OneView offers limited support tor HPE Primera because of the firmware differences

C.

To manage HPE Primera using HPE OneView. a dedicated license is required

D.

Management procedures and features are the same tor both types of the array

Full Access
Question # 7

Which compute node parameters are captured within server hardware type?

A.

Number of the CPUs

B.

installed operating system

C.

Mezzanine card configuration

D.

Size of the memory Installed

Full Access
Question # 8

Which statement about an HPE Oneview support dump is true?

A.

Appliance support dump by default contains a logical enclosure support dump

B.

Support dump is a binary file that can be opened only in a dedicated application

C.

Support dump can be created if HPE Virtual Connect modules are installed in the frame

D.

Preview support dump is available only when creating an appliance support dump

Full Access
Question # 9

Refer to the exhibit.

Which statement about this logical JBOD is true?

A.

This logical JBOD can be connected to multiple systems to formulate a snared datastore.

B.

After deleting this logical JBOD drives will he blocked for 12h m case this JBOD must be re-created

C.

After deleting this logical JBOD, its drives w not be available until a clean-up procedure 6 done

D.

This logical JBOD can be presented to the compute nodes in a different frame.

Full Access
Question # 10

What is a restriction of using a RoCE network?

A.

It is by default configured as an untagged network and cannot be a part of a network set.

B.

It does not support Private VLAN and Multicast VLAN.

C.

it is not supported with HPE Virtual Connect SE 40 GD F8 Module for HPE Synergy.

D.

It does not support smart link and private network features.

Full Access
Question # 11

Your customer manages HPE Synergy using HPE OneView. For one of its projects, the company purchased 50 HPE.

ProLiant DK385 Gen10 Plus v2.They plan to manage the new systems using HPE OneView as well.

What should the customer do to manage rack system using HPE OneView?

A.

add the rack system to the HPE OneView instance used to manage HPE Synergy to centralize management of all systems.

B.

connect the rack system to an IPDU and add the IPDU to the HPE. OneView instance that is used for HPE synergy management.

C.

Deploy HPE OneView Global Dashboard and add the rack systems there, as AMD systems are not directly in HPE OneView.

D.

Deploy an HPE OneView virtual appliance, and, after configuration, use it to manage only the rack systems.

Full Access
Question # 12

Which HPE Virtual Connect feature allows an administrator to suppress excessive inbound multicast broadcast and destination lookup failure (OLF) packets?

A.

Pause flood protection

B.

Loop protection

C.

LLDP tagging

D.

Storm control

Full Access
Question # 13

Your customer is trying to grow a VMware duster using HPE OneView for VMware vCenter Server. They get an error and cannot proceed

Which tool should you use to troubleshoot the problem?

A.

HPE One View for VMware vCenter Server to verify if server profile template s property imported and registered

B.

vCenter Server to verify if an OS Bund Plans property defined and has ESXi image uploaded

C.

HPE OneView interface to import an existing cluster using the hypervisor cluster profile functionality.

D.

ILO interlace of a given HPE Synergy compute node to verify whether this node is registered within HPE Oneview.

Full Access
Question # 14

Your customer plans to deploy a VMware ESXi with HPE Synergy platform. They plan to use Distributed Switches and DRS cluster

You are preparing a proposal with the following components:

- HPE Synergy frame with ten HPE Synergy 480 Gen10 Plus compute modules

- two HPE Virtual Connect SE 100Gb F32 Modules for Synergy

- an appropriate number of the vSphere Standard licenses for each compute node

- one HPE D3940 Storage Modules with 40 SSDs - all required cables and options

Which statement about this proposal is true?

A.

One HPE Virtual Connect SE 100Gb F32 Module for Synergy should be replaced with 50GD/S ILM

B.

vSphere Standard licenses should be replaced with Enterprise Pius licenses to enable requested features

C.

2 additional HPE Synergy 480 Gen10 Plus compute modules can be added to this setup

D.

20 SSD drives should be removed from this setup, as D3940 supports only 20 SSD or SAS drive.

Full Access
Question # 15

Your customer has an HPE Synergy frame equipped with a D3940 Storage Module. Each of the compute nodes has an appropriate storage controller Installed and two 12Gb SAS switches installed in the first fabric.

The customer reports that compute nodes cannot access the storage module. What should you verify first when troubleshooting this problem?

A.

If the D3940 module is imported in managed state that allows volume provisioning.

B.

If there Is a logical interconnect created based on the 12Gb SAS switches.

C.

If the D3940 storage module is property licensed through HPE OneView interface.

D.

If there is at least one ISCSI network configured that will provide access to the module.

Full Access
Question # 16

Click the option that will allow you to change the ESXI image used In an OS Deployment Plan.

Full Access
Question # 17

Your customer plans to add four HPE Synergy frames to an existing management ring Ail installed frames are equipped with two 2-port FLM modules, while new frames will be equipped with 4-port FLM modules.

Which statement about mixing different FLM modules is true?

A.

Existing 2-port FLM modules must be replaced with 4-port FLM modules

B.

A management ring can contain mixed frame link module configurations

C.

A management ring with mixed FLM modules cannot have more than 12 frames

D.

Mixing different FLM modules is allowed if all of them have the same firmware version

Full Access
Question # 18

Your customer reports mat an external FC boot volume for Windows server is visible four times in the Disk Management 1 online and 3 offline.

What should you do to resolve this issue?

A.

Disable deduplication for this volume at the array level

B.

Remove the offline disks using array management tools

C.

Install and configure MPIO on me Windows system

D.

Remove the offline disks using Windows Disk Management

Full Access
Question # 19

What is a limitation when creating a server profile?

A.

BIOS settings can be changed only when UEFI optimized is selected as boot mode

B.

ILO management is limited to the integration with Active Directory or LDAP

C.

Administrator cannot define more than 8 connections within a server profile

D.

It is not possible to create shared volumes on demand through a server profile

Full Access
Question # 20

Match HPE Superdome Flex system with its specific feature.

Full Access
Question # 21

You need to configure a RoCE network to enable lossless networking for HPE J2000 Flash Enclosure support Which interconnects are required to support this connection? (Select two.)

A.

HPE Virtual Connect SE 40Gb F8 Module for HPE Synergy

B.

HPE Virtual Connect SE 16Gb FC Module for HPE Synergy

C.

HPE Virtual Connect SE 100Gb F32 Module for HPE Synergy

D.

HPE Virtual Connect SE 32Gb FC Module for HPE Synergy

E.

Brocade 16Gb Fibfe Channel SAN Switch Module for HPE Synergy

F.

Brocade 32Gb Fibre Channel SAN Switch Module for HPE Synergy

Full Access
Question # 22

Match each HPE Synergy logical component with the definition.

Full Access
Question # 23

Match HPE SimpliVity term with the definition.

Full Access