H19-311 Huawei Certified Pre-sales Associate- Data Center Facility Question and Answers

Question # 4

Which of the following problems shall be considered when selecting the UPS cable? (Multiple Choice)

A.

Rated current of the UPS

B.

Rated operating voltage and insulating voltage of the power cable

C.

Voltage drop of the power cable in the route

D.

Number of the parallel cables

Full Access
Question # 5

The UPS5000-E can realize convenient and simple N+X power supply system only by configuring a ().

A.

BSC cable

B.

Parallel cable

C.

BSC control board

D.

Parallel card

Full Access
Question # 6

The UPS5000-A-4O0/500K has good scalability, supporting a maximum of Q to be used in parallel.

A.

2

B.

3

C.

4

D.

6

Full Access
Question # 7

The output power factor of the UPS2000-G series (6 kVA to 20 kVA) is (), which adapts to new types of IT loads and greatly improves the system loading capability.

A.

0.7

B.

0.8

C.

0.9

D.

0.99

Full Access
Question # 8

The Fusion Mod ule500 and FusionModule800 support the use of 24 U and 42 U cabinets.

A.

TRUE

B.

FALSE

Full Access
Question # 9

What differentiated features does the FusionModule800 have over competing products? () (Multiple Choice)

A.

Rack-mounted frequency-converting air conditioner

B.

Integrated design of cooling and power

C.

Light-load dehumidification of air conditioning

D.

iBattery

Full Access
Question # 10

Which of the following functions can a modular UPS realize? (Multiple Choice)

A.

Online expansion

B.

Online hot swap

C.

2N redundancy configuration for a single UPS

D.

N+X redundancy configuration for a single UPS

Full Access
Question # 11

Compared with the industrial frequency UPS with the SCR, the high frequency UPS with the IGBT rectifier can greatly reduce the input current harmonics and improve the input power factor.

A.

TRUE

B.

FALSE

Full Access
Question # 12

In the SCT configurator, you can click the question mark (?) to view the parameter's help information.

A.

TRUE

B.

FALSE

Full Access
Question # 13

Which of the following UPS types does the PS5000-E (50 kVA power module) belongs to? (Multiple Choice)

A.

Industrial frequency UPS

B.

High frequency UPS

C.

Rack and tower-mounted UPS

D.

Modular UPS

Full Access
Question # 14

A cable of which the total carrying capacity is greater than the rated UPS current can satisfy the requirements of the project.

A.

TRUE

B.

FALSE

Full Access
Question # 15

For two UPS5000-E (50 kA power module) 150 kVA with 2+0 rack redundancy, a () general input switch is required for the general input power distribution cabinet.

A.

250 A

B.

320 A

C.

500 A

D.

630 A

Full Access
Question # 16

The number of battery strings for the UPS5000-E (50 kVA power module) can be adjusted. To avoid replacing the whole battery string due to one faulty battery and solve the battery maintenance difficulty of traditional UPSs, the adjustable number of batteries in the UPS5000-E ranges from 30 to 44.

A.

TRUE

B.

FALSE

Full Access
Question # 17

Which of the following statements are correct about UPS5000-E bypass overload capacity? (Multiple Choice)

A.

125% overload for 10 minutes

B.

125% overload for 60 minutes

C.

135% overload for a long time

D.

1000% overload for 100 ms

Full Access
Question # 18

The UPS2000-G series (1 kVA to 3 kVA) supports ( ) UPSs in parallel.

A.

2

B.

3

C.

4

Full Access
Question # 19

When using a UPS5000-E (50 kVA power module) with the actual load of 160 kW, 1+1 rack redundancy, and single UPS backup solution, each rack uses three battery strings, each battery string consists of 40 batteries, and the main switch box capacity is ().

A.

250A

B.

320 A

C.

500 A

D.

630 A

Full Access
Question # 20

Which of the following types does the UPS5000-A belong to?

A.

High frequency UPS and modular UPS

B.

High-frequency tower-mounted UPS

C.

Industrial frequency UPS

Full Access
Question # 21

Which of the following models can be equipped with external high capacity battery charger for rapid recharge?

A.

UPS5000-A

B.

UPS5000-E

C.

UPS2000-A 6/10K professional standard

D.

UPS2000-G 6K extended

Full Access
Question # 22

The optional components and features in the typical configuration solution of the FusionModule800 include ().

A.

Temperature and humidity sensor, door status sensor, water sensor, smoke sensor, and mobile app

B.

Smoke sensor, door status sensor, water sensor, alarm notification over short messages, and Huawei tablet

C.

Door magnetic switch, Water leakage, Video system. Power backup system, iBattery, Mobile APP (remote), Emergency fans

Full Access
Question # 23

The UPS2000-G is designed with high power density, with 2 U height for the 6 kVA and 10 kVA capacity models and 3 U height for the 15 kVA and 20 kVA capacity models.

A.

TRUE

B.

FALSE

Full Access
Question # 24

What type of air conditioner does the Fusion Mod ule800 basic configurations adopt? () (Multiple Choice)

A.

In-row air conditioner

B.

Rack-mounted air conditioner

C.

Air cooling

D.

Water cooling

E.

Air conditioner with a heater and humidifier

F.

Cooling only

Full Access
Question # 25

As the construction cost of the equipment room is high, reducing the floor area can efficiently save investment for clients. The floor area of a UPS5000-A-500K is ().

A.

1.02 m2

B.

2m2

C.

0.51 m2

Full Access
Question # 26

The highest temperature in the local area is () when selects T3 air conditioning?

A.

30-35°C

B.

35-43°C

C.

43-55°C

D.

55-65°C

Full Access
Question # 27

When configuring batteries, you do not need to consider the battery brand as long as the capacity satisfies customer requirements.

A.

TRUE

B.

FALSE

Full Access
Question # 28

Which of the following components is optional for the UPS5000-E (25-75 kVA)? (Multiple Choice)

A.

Anti-seismic kit

B.

Top outlet kit

C.

Ambient temperature and humidity sensor

D.

BSC cable

Full Access
Question # 29

The UPS5000-A features industry-leading reliability. Which of the following statements is correct about the UPS5000-A reliability design? (Multiple Choice)

A.

Strong power grid adaptability, 138-485 V voltage input range

B.

Conformal coated board

C.

Test guarantee of 1,400 items

D.

40°C without derating

Full Access
Question # 30

The UPS2000-G series (6 kVA to 20 kVA) supports backup power supplied from battery packs and battery racks. Battery packs can be mounted on racks to save installation space.

A.

TRUE

B.

FALSE

Full Access
Question # 31

For the UPS2000-G series (6 kVA to 20 kVA), the main input voltage ranges from 80 V to 280 V, and the input frequency ranges from 40 Hz to 70 Hz. A wide input range effectively reduces the battery switch times, failure probability, and battery charge/discharge times, helping improve the battery life.

A.

TRUE

B.

FALSE

Full Access
Question # 32

The UPS2000-G supports low voltage disconnection. Which of the following is not a function of low voltage disconnection? ()

A.

When overload occurs, secondary loads are closed to remove the overload.

B.

When the UPS2000-G is powered by batteries, secondary loads are closed to prolong the backup time for important loads.

C.

When the UPS2000-G is powered by batteries, secondary loads are closed for battery protection.

D.

The purpose of closing secondary loads is to adjust the load ratio and optimize the operating efficiency.

Full Access
Question # 33

APM and NXR need to derate at 30°C, while the UPS5000-E does not need to derate below 40°C.

A.

TRUE

B.

FALSE

Full Access