A customer notices a volume is using an above average amount of Tier 1 RAID 10 space. What can be done to force this data into a lower RAID set/Tier?
A customer wants to add an iSCSI path to a Microsoft Windows Server 2012 R1. The server has an existing Fibre Channel path to an SC7020 array for load balancing and high availability.
Which Windows MPIO policy should be configured to achieve the customer’s requirement?
You want to create a notification setting to help monitor how full the volumes are on an SC9000 system. In Dell Storage Manager (DSM), where would a schedule to only trigger these alerts during business hours be set up?
When performing the initial configuration on an SC9000 through the serial port, which command is used to reboot the controller?
A customer has a space of 20U available on the rack that already houses a SCv3020 array. How many expansion SCv360 enclosures can be installed in the available space?
What is the recommended minimum number of ports per controller, per fault domain, to support port-level failover?
During the initial installation of a new SC9000 Storage Center, which Dell Storage Manager (DSM) Client option should be selected?
Assume a storage administrator is using the recommended storage profile. What describes the distribution of volume data residing in an SC series storage array that has 15K and 7K as the back-end?
You just finished racking a SC7020 array. After powering it on, you notice there is no indicator LED on the front or back of the array, but the fans are spinning.
What could be the cause?
ON NO: 83
When connecting directly to an SC7020 storage array using Dell Storage Manager Client, which host/IP address is entered into the login screen?
You have connected a 12 GB expansion enclosure using Mini-SAS HD cables. When powered on, some of the cable do not show a link. Why?
An administrator wants to configure an SC Series array to use Virtual Port Mode. What is a requirement to accomplish this task?
What is order of steps that the Storage Center will follow when it senses that the UPS has lost input power?
A customer is running the Dell Storage Manager (DSM) Suite as a software stack on Microsoft Windows. To reduce the Microsoft licensing costs, the customer wants to switch to the DSM Virtual Appliance.
Which recommended deployment should the customer use?
When installing an SC Series array, the customer indicated that they want the controller configured to provide the maximum amount of storage space. You discover that the storage controller was shipped with twelve 900 GB drives and twelve 1.8 TB drives of the same type.
Which redundancy level can be selected to provide the maximum amount of storage?
You are installing a new FC switch to an existing fabric. You are receiving a Zone conflict error. Why?
You are installing an SC8000 array and the customer notices that each of the controllers only have 16 GB of memory. The customer wants to maximize this memory. What is the maximum RAM supported on a single SC8000 controller?