Home > EMC > DCS-PE > DES-1241

DES-1241 Specialist - Platform Engineer PowerStore Exam Question and Answers

Question # 4

Correctly order the steps of the embedded module replacement procedure.

Full Access
Question # 5

During Dell EMC PowerStore startup, both appliance nodes have rebooted in service mode. What must be done first to avoid management software conflicts?

A.

Reboot node B

B.

Clear the boot mode

C.

Disable node B boot mode

D.

Return node A to normal mode

Full Access
Question # 6

A Storage Administrator needs to address specific fixes within their Dell EMC PowerStore system. Which NDU software upgrade option is used for this situation?

A.

Hotfixes

B.

vCenter

C.

Drive firmware

D.

Software releases

Full Access
Question # 7

Refer to the exhibit.

Which column indicates the master appliance?

A.

IP Address

B.

Model

C.

Service Tag

D.

Mode

Full Access
Question # 8

A Storage Administrator has an existing single appliance Dell EMC PowerStore 3000T cluster. An additional PowerStore 9000T has been purchased to add into the existing cluster.

How does the administrator proceed?

A.

Additional VLTi links on the ToR switching must be configured for the 9000T to support the increased inter-switch network load

B.

Add the new 9000T appliance into the cluster per the procedure; mixed models of the same type are supported

C.

Remove two of the four NVMe NVRAM drives from the 9000T the caching configuration of all clustered appliances must match

D.

The new appliance cannot be added to the cluster; appliance model and type must match when clustering appliances together

Full Access
Question # 9

While on-site troubleshooting a Dell EMC PowerStore system, the node Ð’ embedded module fault LED is blinking blue and amber alternating at one second intervals. What does this indicate?

A.

Node is in degraded mode

B.

Node is booting

C.

Node is on service mode

D.

System is not initialized

Full Access
Question # 10

A Storage Administrator notices a Major alert present in Dell EMC PowerStore Manager relating to data protection. What action within the alert details slide-out panel is helpful in troubleshooting the data protection problem?

A.

View the Associated Events for earlier related alerts

B.

Examine Notifications to obtain a list of corrective actions

C.

Acknowledge the alert to clear and resolve the problem

D.

Access the Repair Flow link to schedule a support engagement

Full Access
Question # 11

What safety equipment is critical to have on hand to avoid equipment failure before replacing any components in a Dell EMC PowerStore array?

A.

Maintenance Kit

B.

ESD Kit

C.

Stabilization Kit

D.

Rail Kit

Full Access
Question # 12

Match the correct non-disruptive upgrade process step (answer column) with the correct sub-step (match column).

Full Access
Question # 13

Which component is an FRU?

A.

DIMMs

B.

Embedded IO Module

C.

Nodes

D.

Battery Backup Unit

Full Access
Question # 14

Which network is used for internal communication?

A.

Intra-Cluster Data

B.

Intra-Cluster Management

C.

NAD Network

D.

Inter-Node Network