Question # 4

An SRDF/Metro Smart DR configuration experiences a service interruption.

What criteria will the Fault-Aware Witness give a higher priority to when selecting the winning array?

A.

Synced SRDF/A leg

B.

Director status

C.

Presence of a DR leq

D.

Bias

Full Access
Question # 5

Refer to exhibit.

The RDF-ECA timer has expired.

What is the state of all the RDF links?

A.

failed over

B.

suspend

C.

online

D.

split

Full Access
Question # 6

What is the correct sequence of steps to configure and bring up an SRDF/Star environment?

Full Access
Question # 7

What is the correct sequence of actions that take place on a Write Miss?

Full Access
Question # 8

A DG group is part of a snapshot schedule which runs each day at 9 am then linked to a set of targets for a full copy after termination. Additional volumes were added which increased the link to full copy time.

What course of action will prevent the issue?

A.

Set copy to URGENT

B.

Relink with the -precopy option

C.

Set copy pace 16

D.

Relink without the -copy option

Full Access
Question # 9

What is the minimum number of samples that must be collected via a single Real Time Trace collection process in Unisphere for PowerMax?

A.

130

B.

1040

C.

360

D.

720

Full Access
Question # 10

Alerts are required to track high I/O response times for a specific storage group. I/O Response times greater than 10 ms require next day analysis. I/O response times greater than 15 ms require immediate intervention.

Which alert settings are required?

A.

1st level - Warning, 10 ms 2nd level - Critical, 15 ms

B.

1st level-Warning, 11 ms 2nd level - Critical, 16 ms

C.

1st level - Informational, 10 ms. 2nd level - Warning, 15 ms

D.

1st level - informational, 9 ms 2nd level - Warning, 14 ms

Full Access
Question # 11

A disaster occurred at the workload site of an SRDF/Star configuration. The administrator decides to move the workload to the Synchronous site (Site B).

What symstar command should be used before the workload switch?

A.

disable

B.

halt

C.

unpFOlecl

D.

cleanup

Full Access
Question # 12

An application server has the following data characteristics:

80% of the I/O is generated with 8 KB random small blocks

20% of the I/O is generated with 64 KB sequential large blocks

50% of all I/O is a write

What workload profile do these data characteristics represent?

A.

RWM

B.

RRH

C.

DCS

D.

OLTP

Full Access
Question # 13

SRDF/A MSC has been configured between two sites. There are two PowerMax arrays at the source site and two PowerMax arrays at the target site. An SRDF/A MSC trip event has occurred.

What happens if the Receive Delta Set on one of the target arrays is incomplete?

A.

Transmit Delta set is discarded

B.

Session is marked as No Cleanup required

C.

Receive Delta Set data is discarded

D.

Session is marked as Cleanup required

Full Access
Question # 14

NDM is being used to migrate some Windows hosts to a new PowerMax. The client doesn't want the migration target volumes to retain the source volume external device identity following the migration.

What should be used to complete the migration and address the client's concern?

A.

NDM cancel revert function

B.

NDM Updates feature

C.

NDM pass-through mode

D.

NDM metro-based mode